Small changes after FAT and EMS Test
- Changed Modbus server config for EMS connectivity - Changed some default EWL Limits
This commit is contained in:
@@ -1,5 +1,5 @@
|
|||||||
<?xml version="1.0" encoding="utf-8"?>
|
<?xml version="1.0" encoding="utf-8"?>
|
||||||
<safetyApplicationLanguageDiagram Crc="3764738484" dslVersion="1.4.0.0" Id="10165380-5ad4-4a1c-ba25-e8b86a8e4001" absoluteBounds="0, 0, 12.375, 8.5" name="TwinSAFE">
|
<safetyApplicationLanguageDiagram Crc="1400438383" dslVersion="1.5.0.0" Id="10165380-5ad4-4a1c-ba25-e8b86a8e4001" absoluteBounds="0, 0, 12.375, 8.5" name="TwinSAFE">
|
||||||
<safetyApplicationMoniker name="/" />
|
<safetyApplicationMoniker name="/" />
|
||||||
<nestedChildShapes>
|
<nestedChildShapes>
|
||||||
<networkSwimLane Id="e01f4458-df70-481e-ae9d-4f44a16fbcf1" absoluteBounds="0, 0, 12.375, 5.325">
|
<networkSwimLane Id="e01f4458-df70-481e-ae9d-4f44a16fbcf1" absoluteBounds="0, 0, 12.375, 5.325">
|
||||||
|
|||||||
@@ -87,7 +87,7 @@ VAR_GLOBAL PERSISTENT
|
|||||||
|
|
||||||
// Pressure posolyt tank inlet
|
// Pressure posolyt tank inlet
|
||||||
stConfigPosolytPressureTankInlet := (iAIMax := 32767, iAIMin := 0, rPVMax := 2000, rPVMin := 0, sUnit := 'mbar'),
|
stConfigPosolytPressureTankInlet := (iAIMax := 32767, iAIMin := 0, rPVMax := 2000, rPVMin := 0, sUnit := 'mbar'),
|
||||||
stEWLPosolytPressureTankInlet := (rErrorMin := -20, rWarningMin := -10, rWarningMax := 15, rErrorMax := 25),
|
stEWLPosolytPressureTankInlet := (rErrorMin := -20, rWarningMin := -10, rWarningMax := 50, rErrorMax := 75),
|
||||||
stEWDPosolytPressureTankInlet :=
|
stEWDPosolytPressureTankInlet :=
|
||||||
(
|
(
|
||||||
timHardwareSignalLevelOn := T#0S,
|
timHardwareSignalLevelOn := T#0S,
|
||||||
@@ -104,7 +104,7 @@ VAR_GLOBAL PERSISTENT
|
|||||||
|
|
||||||
// Pressure negolyt tank inlet
|
// Pressure negolyt tank inlet
|
||||||
stConfigNegolytPressureTankInlet := (iAIMax := 32767, iAIMin := 0, rPVMax := 2000, rPVMin := 0, sUnit := 'mbar'),
|
stConfigNegolytPressureTankInlet := (iAIMax := 32767, iAIMin := 0, rPVMax := 2000, rPVMin := 0, sUnit := 'mbar'),
|
||||||
stEWLNegolytPressureTankInlet := (rErrorMin := -20, rWarningMin := -10, rWarningMax := 15, rErrorMax := 25),
|
stEWLNegolytPressureTankInlet := (rErrorMin := -20, rWarningMin := -10, rWarningMax := 50, rErrorMax := 75),
|
||||||
stEWDNegolytPressureTankInlet :=
|
stEWDNegolytPressureTankInlet :=
|
||||||
(
|
(
|
||||||
timHardwareSignalLevelOn := T#0S,
|
timHardwareSignalLevelOn := T#0S,
|
||||||
@@ -121,7 +121,7 @@ VAR_GLOBAL PERSISTENT
|
|||||||
|
|
||||||
// Temperature sensor posolyt tank inlet
|
// Temperature sensor posolyt tank inlet
|
||||||
stConfigPosolytTempTankInlet := (iAIMax := 32767, iAIMin := -32768, rPVMax := 3276.7, rPVMin := -3276.8, sUnit := '°C'),
|
stConfigPosolytTempTankInlet := (iAIMax := 32767, iAIMin := -32768, rPVMax := 3276.7, rPVMin := -3276.8, sUnit := '°C'),
|
||||||
stEWLPosolytTempTankInlet := (rErrorMin := 10, rWarningMin := 15, rWarningMax := 50, rErrorMax := 60),
|
stEWLPosolytTempTankInlet := (rErrorMin := 10, rWarningMin := 15, rWarningMax := 42, rErrorMax := 45),
|
||||||
stEWDPosolytTempTankInlet :=
|
stEWDPosolytTempTankInlet :=
|
||||||
(
|
(
|
||||||
timHardwareSignalLevelOn := T#0S,
|
timHardwareSignalLevelOn := T#0S,
|
||||||
@@ -138,7 +138,7 @@ VAR_GLOBAL PERSISTENT
|
|||||||
|
|
||||||
// Temperature sensor negolyt tank inlet
|
// Temperature sensor negolyt tank inlet
|
||||||
stConfigNegolytTempTankInlet := (iAIMax := 32767, iAIMin := -32768, rPVMax := 3276.7, rPVMin := -3276.8, sUnit := '°C'),
|
stConfigNegolytTempTankInlet := (iAIMax := 32767, iAIMin := -32768, rPVMax := 3276.7, rPVMin := -3276.8, sUnit := '°C'),
|
||||||
stEWLNegolytTempTankInlet := (rErrorMin := 15, rWarningMin := 15, rWarningMax := 50, rErrorMax := 60),
|
stEWLNegolytTempTankInlet := (rErrorMin := 15, rWarningMin := 15, rWarningMax := 42, rErrorMax := 45),
|
||||||
stEWDNegolytTempTankInlet :=
|
stEWDNegolytTempTankInlet :=
|
||||||
(
|
(
|
||||||
timHardwareSignalLevelOn := T#0S,
|
timHardwareSignalLevelOn := T#0S,
|
||||||
@@ -158,7 +158,7 @@ VAR_GLOBAL PERSISTENT
|
|||||||
// Index 0x80n0:02 "Presentation" = Signed(0) -> Resolution 1/10°C
|
// Index 0x80n0:02 "Presentation" = Signed(0) -> Resolution 1/10°C
|
||||||
// Index 0x80n0:19 "RTD Element" = PT100(0)
|
// Index 0x80n0:19 "RTD Element" = PT100(0)
|
||||||
stConfigVoltageSegment := (iAIMax := 32767, iAIMin := 0, rPVMax := 150, rPVMin := 0, sUnit := 'V'),
|
stConfigVoltageSegment := (iAIMax := 32767, iAIMin := 0, rPVMax := 150, rPVMin := 0, sUnit := 'V'),
|
||||||
stEWLVoltageSegment := (rErrorMin := 50, rWarningMin := 55, rWarningMax := 77, rErrorMax := 80),
|
stEWLVoltageSegment := (rErrorMin := 50, rWarningMin := 54, rWarningMax := 79, rErrorMax := 80),
|
||||||
stEWDVoltageSegment :=
|
stEWDVoltageSegment :=
|
||||||
(
|
(
|
||||||
timHardwareSignalLevelOn := T#0S,
|
timHardwareSignalLevelOn := T#0S,
|
||||||
@@ -195,10 +195,10 @@ VAR_GLOBAL PERSISTENT
|
|||||||
rPumpNegolytOnPower : REAL := 70.0;
|
rPumpNegolytOnPower : REAL := 70.0;
|
||||||
|
|
||||||
// Pump posolyt discharge segment without inverter power in %
|
// Pump posolyt discharge segment without inverter power in %
|
||||||
rPumpPosolytDisChrgPower : REAL := 45.0;
|
rPumpPosolytDisChrgPower : REAL := 50.0;
|
||||||
|
|
||||||
// Pump posolyt discharge segment without inverter power in %
|
// Pump posolyt discharge segment without inverter power in %
|
||||||
rPumpNegolytDisChrgPower : REAL := 45.0;
|
rPumpNegolytDisChrgPower : REAL := 50.0;
|
||||||
|
|
||||||
// Unit voltage pumps shutoff threshold (Volt)
|
// Unit voltage pumps shutoff threshold (Volt)
|
||||||
rPumpshutoffThreshold : REAL := 15.0;
|
rPumpshutoffThreshold : REAL := 15.0;
|
||||||
@@ -207,7 +207,7 @@ VAR_GLOBAL PERSISTENT
|
|||||||
rMinimumUnitVoltage : REAL := 55.0;
|
rMinimumUnitVoltage : REAL := 55.0;
|
||||||
|
|
||||||
// Maximum unit voltage for fully charged (Volt)
|
// Maximum unit voltage for fully charged (Volt)
|
||||||
rMaximumUnitVoltage : REAL := 79.5;
|
rMaximumUnitVoltage : REAL := 78.5;
|
||||||
|
|
||||||
// Delta value to minimum unit voltage for shutdown discharge (Volt)
|
// Delta value to minimum unit voltage for shutdown discharge (Volt)
|
||||||
rDeltaUnitVoltageShutdownDischarge : REAL := 5.0;
|
rDeltaUnitVoltageShutdownDischarge : REAL := 5.0;
|
||||||
@@ -225,11 +225,11 @@ VAR_GLOBAL PERSISTENT
|
|||||||
|
|
||||||
// Maximum allowed charging power (Watt) per String
|
// Maximum allowed charging power (Watt) per String
|
||||||
// 24.000 W -> 2.000 W per Unit
|
// 24.000 W -> 2.000 W per Unit
|
||||||
diMaxStringChargingPower : DINT := -50_000;
|
diMaxStringChargingPower : DINT := -48_000;
|
||||||
|
|
||||||
// Maximum allowed discharging power (Watt) per String
|
// Maximum allowed discharging power (Watt) per String
|
||||||
// 24.000 W -> 2.000 W per Unit
|
// 24.000 W -> 2.000 W per Unit
|
||||||
diMaxStringDischargePower : DINT := 50_000;
|
diMaxStringDischargePower : DINT := 48_000;
|
||||||
|
|
||||||
// Inverter ip address for string 1
|
// Inverter ip address for string 1
|
||||||
sInverterIpString1 : STRING := '192.168.42.10';
|
sInverterIpString1 : STRING := '192.168.42.10';
|
||||||
@@ -252,7 +252,7 @@ VAR_GLOBAL PERSISTENT
|
|||||||
rStringEmptyVoltage : REAL := 660.0;
|
rStringEmptyVoltage : REAL := 660.0;
|
||||||
|
|
||||||
// Unit wait startup time (was 1 minute, reduced because of Doppelhöcker-Test)
|
// Unit wait startup time (was 1 minute, reduced because of Doppelhöcker-Test)
|
||||||
timUnitStartupTime : TIME := T#5S;
|
timUnitStartupTime : TIME := T#15S;
|
||||||
|
|
||||||
// Unit balancing wait startup time
|
// Unit balancing wait startup time
|
||||||
timUnitBalancingStartupTime : TIME := T#3M;
|
timUnitBalancingStartupTime : TIME := T#3M;
|
||||||
|
|||||||
418
PLC/PLC.tmc
418
PLC/PLC.tmc
File diff suppressed because one or more lines are too long
@@ -549,6 +549,9 @@ CASE _iState OF
|
|||||||
_tonErrorDCCBNotClosed.IN := FALSE;
|
_tonErrorDCCBNotClosed.IN := FALSE;
|
||||||
xError := TRUE;
|
xError := TRUE;
|
||||||
xReady := FALSE;
|
xReady := FALSE;
|
||||||
|
IF (NOT _fbDCMainSwitchNotClosed.bRaised) THEN
|
||||||
|
_fbDCMainSwitchNotClosed.Raise(0);
|
||||||
|
END_IF
|
||||||
_iState := 1000;
|
_iState := 1000;
|
||||||
END_IF
|
END_IF
|
||||||
|
|
||||||
@@ -770,6 +773,7 @@ CASE _iState OF
|
|||||||
IF (NOT xEnable) AND (NOT _xErrorInternal) THEN
|
IF (NOT xEnable) AND (NOT _xErrorInternal) THEN
|
||||||
xError := FALSE;
|
xError := FALSE;
|
||||||
_xReleaseSafetyIntlkErrors := FALSE;
|
_xReleaseSafetyIntlkErrors := FALSE;
|
||||||
|
ClearAlarms();
|
||||||
//eStatus := E_COMPONENT_STATUS.OFF;
|
//eStatus := E_COMPONENT_STATUS.OFF;
|
||||||
_iState := 0;
|
_iState := 0;
|
||||||
END_IF
|
END_IF
|
||||||
@@ -843,6 +847,13 @@ stHMIInterface.eStatus := eStatus;
|
|||||||
// Reset Safety
|
// Reset Safety
|
||||||
xResetSafetyDCCB := xResetSafety;]]></ST>
|
xResetSafetyDCCB := xResetSafety;]]></ST>
|
||||||
</Implementation>
|
</Implementation>
|
||||||
|
<Action Name="ClearAlarms" Id="{541a307f-e5d8-4588-8fd3-6f4bdf6a71dd}">
|
||||||
|
<Implementation>
|
||||||
|
<ST><![CDATA[IF _fbDCMainSwitchNotClosed.bRaised THEN
|
||||||
|
_fbDCMainSwitchNotClosed.Clear(0, FALSE);
|
||||||
|
END_IF]]></ST>
|
||||||
|
</Implementation>
|
||||||
|
</Action>
|
||||||
<Method Name="FB_init" Id="{9e8494eb-1b40-4be9-91c8-810ecbdf7f0c}">
|
<Method Name="FB_init" Id="{9e8494eb-1b40-4be9-91c8-810ecbdf7f0c}">
|
||||||
<Declaration><![CDATA[METHOD FB_init : BOOL
|
<Declaration><![CDATA[METHOD FB_init : BOOL
|
||||||
VAR_INPUT
|
VAR_INPUT
|
||||||
|
|||||||
@@ -156,6 +156,8 @@ VAR
|
|||||||
_rMinCurrentInverterDCVoltage : REAL;
|
_rMinCurrentInverterDCVoltage : REAL;
|
||||||
|
|
||||||
_fbModbusRead : FB_MBReadRegs;
|
_fbModbusRead : FB_MBReadRegs;
|
||||||
|
// _fbModbusWrite : FB_MBWriteSingleReg;
|
||||||
|
// _fbModbusWriteMult : FB_MBWriteRegs;
|
||||||
//_wLength : WORD := 49;
|
//_wLength : WORD := 49;
|
||||||
xDebugTest : BOOL;
|
xDebugTest : BOOL;
|
||||||
_wDebug1 : WORD;
|
_wDebug1 : WORD;
|
||||||
@@ -172,12 +174,58 @@ VAR
|
|||||||
_rPowerDH : REAL;
|
_rPowerDH : REAL;
|
||||||
_fbTONDHCycleTime : TON := (PT := T#15M);
|
_fbTONDHCycleTime : TON := (PT := T#15M);
|
||||||
|
|
||||||
|
//_uiTest : UINT := 1;
|
||||||
|
//_diTest : DINT := 123;
|
||||||
|
|
||||||
//_fbKaco : FB_PowerSupplyKaco('Kaco');
|
//_fbKaco : FB_PowerSupplyKaco('Kaco');
|
||||||
//_xEnableKaco : BOOL;
|
//_xEnableKaco : BOOL;
|
||||||
END_VAR
|
END_VAR
|
||||||
]]></Declaration>
|
]]></Declaration>
|
||||||
<Implementation>
|
<Implementation>
|
||||||
<ST><![CDATA[IF _xFirstCycle THEN
|
<ST><![CDATA[(*
|
||||||
|
IF xDebugTest THEN
|
||||||
|
(*
|
||||||
|
_fbModbusWrite(
|
||||||
|
sIPAddr:= '127.0.0.1',
|
||||||
|
nTCPPort:= 502,
|
||||||
|
nUnitID:= 16#FF,
|
||||||
|
nMBAddr:= 13004,
|
||||||
|
nValue:= 1,
|
||||||
|
bExecute:= TRUE,
|
||||||
|
tTimeout:= T#10S,
|
||||||
|
bBusy=> ,
|
||||||
|
bError=> ,
|
||||||
|
nErrId=> );
|
||||||
|
|
||||||
|
IF (NOT _fbModbusWrite.bBusy) THEN
|
||||||
|
xDebugTest := FALSE;
|
||||||
|
_fbModbusWrite(bExecute := FALSE);
|
||||||
|
END_IF
|
||||||
|
*)
|
||||||
|
|
||||||
|
_fbModbusWriteMult(
|
||||||
|
sIPAddr:= '127.0.0.1',
|
||||||
|
nTCPPort:= 502,
|
||||||
|
nUnitID:= 16#FF,
|
||||||
|
nQuantity:= 2,
|
||||||
|
nMBAddr:= 12000,
|
||||||
|
cbLength:= SIZEOF(_diTest),
|
||||||
|
pSrcAddr:= ADR(_diTest),
|
||||||
|
bExecute:= TRUE,
|
||||||
|
tTimeout:= T#10S,
|
||||||
|
bBusy=> ,
|
||||||
|
bError=> ,
|
||||||
|
nErrId=> );
|
||||||
|
|
||||||
|
IF (NOT _fbModbusWriteMult.bBusy) THEN
|
||||||
|
xDebugTest := FALSE;
|
||||||
|
_fbModbusWriteMult(bExecute := FALSE);
|
||||||
|
END_IF
|
||||||
|
END_IF
|
||||||
|
*)
|
||||||
|
|
||||||
|
|
||||||
|
IF _xFirstCycle THEN
|
||||||
_xFirstCycle := FALSE;
|
_xFirstCycle := FALSE;
|
||||||
_xGetPowerMeterData := TRUE;
|
_xGetPowerMeterData := TRUE;
|
||||||
|
|
||||||
@@ -217,6 +265,7 @@ IF GVL_MODBUS.stBMSErrorReg.wConfirmAlarms > 0 THEN
|
|||||||
_xConfirmAlarms := TRUE;
|
_xConfirmAlarms := TRUE;
|
||||||
END_IF
|
END_IF
|
||||||
|
|
||||||
|
|
||||||
// Ack alarms from hardware button
|
// Ack alarms from hardware button
|
||||||
_fbRTrigHardwareAck(CLK := _xHarwareResetButton);
|
_fbRTrigHardwareAck(CLK := _xHarwareResetButton);
|
||||||
IF _fbRTrigHardwareAck.Q THEN
|
IF _fbRTrigHardwareAck.Q THEN
|
||||||
|
|||||||
@@ -269,7 +269,7 @@
|
|||||||
</System>
|
</System>
|
||||||
<Plc>
|
<Plc>
|
||||||
<Project GUID="{9AE64910-5EB2-4866-93FD-EFE059C38C36}" Name="PLC" PrjFilePath="PLC\PLC.plcproj" TmcFilePath="PLC\PLC.tmc" ReloadTmc="true" AmsPort="851" FileArchiveSettings="#x000e" CopyTmcToTarget="true" CopyTpyToTarget="false" SymbolicMapping="true">
|
<Project GUID="{9AE64910-5EB2-4866-93FD-EFE059C38C36}" Name="PLC" PrjFilePath="PLC\PLC.plcproj" TmcFilePath="PLC\PLC.tmc" ReloadTmc="true" AmsPort="851" FileArchiveSettings="#x000e" CopyTmcToTarget="true" CopyTpyToTarget="false" SymbolicMapping="true">
|
||||||
<Instance Id="#x08502000" TcSmClass="TComPlcObjDef" KeepUnrestoredLinks="2" TmcHash="{230A3C79-804C-4ED1-6C6E-6C3CE2FDFC9C}" TmcPath="PLC\PLC.tmc">
|
<Instance Id="#x08502000" TcSmClass="TComPlcObjDef" KeepUnrestoredLinks="2" TmcHash="{B6610D51-FC43-AAD1-46A6-1C271CAEF439}" TmcPath="PLC\PLC.tmc">
|
||||||
<Name>PLC Instance</Name>
|
<Name>PLC Instance</Name>
|
||||||
<CLSID ClassFactory="TcPlc30">{08500001-0000-0000-F000-000000000064}</CLSID>
|
<CLSID ClassFactory="TcPlc30">{08500001-0000-0000-F000-000000000064}</CLSID>
|
||||||
<Vars VarGrpType="2" AreaNo="1">
|
<Vars VarGrpType="2" AreaNo="1">
|
||||||
@@ -6889,11 +6889,6 @@
|
|||||||
<Comment><![CDATA[ Hardware reset button]]></Comment>
|
<Comment><![CDATA[ Hardware reset button]]></Comment>
|
||||||
<Type>BOOL</Type>
|
<Type>BOOL</Type>
|
||||||
</Var>
|
</Var>
|
||||||
<Var>
|
|
||||||
<Name>MAIN._uiEtherCATState</Name>
|
|
||||||
<Comment><![CDATA[ String EtherCAT state]]></Comment>
|
|
||||||
<Type>UINT</Type>
|
|
||||||
</Var>
|
|
||||||
<Var>
|
<Var>
|
||||||
<Name>MAIN._fbSafety.xVoltagesInRange</Name>
|
<Name>MAIN._fbSafety.xVoltagesInRange</Name>
|
||||||
<Type>BOOL</Type>
|
<Type>BOOL</Type>
|
||||||
@@ -6906,6 +6901,11 @@
|
|||||||
<Name>MAIN._fbSafety.xTemperaturesInRange</Name>
|
<Name>MAIN._fbSafety.xTemperaturesInRange</Name>
|
||||||
<Type>BOOL</Type>
|
<Type>BOOL</Type>
|
||||||
</Var>
|
</Var>
|
||||||
|
<Var>
|
||||||
|
<Name>MAIN._uiEtherCATState</Name>
|
||||||
|
<Comment><![CDATA[ String EtherCAT state]]></Comment>
|
||||||
|
<Type>UINT</Type>
|
||||||
|
</Var>
|
||||||
</Vars>
|
</Vars>
|
||||||
<Contexts>
|
<Contexts>
|
||||||
<Context>
|
<Context>
|
||||||
|
|||||||
@@ -66,7 +66,7 @@
|
|||||||
</Hides>
|
</Hides>
|
||||||
</DataType>
|
</DataType>
|
||||||
<DataType>
|
<DataType>
|
||||||
<Name GUID="{4B5D56D2-4431-41C5-8F0A-06E1FC56151A}">BMSEvents</Name>
|
<Name GUID="{58BB5280-6EA8-4841-8B84-F66A8442CCAE}">BMSEvents</Name>
|
||||||
<DisplayName TxtId=""><![CDATA[String event class]]></DisplayName>
|
<DisplayName TxtId=""><![CDATA[String event class]]></DisplayName>
|
||||||
<EventId>
|
<EventId>
|
||||||
<Name Id="1">NotAllCompInAuto</Name>
|
<Name Id="1">NotAllCompInAuto</Name>
|
||||||
@@ -128,6 +128,11 @@
|
|||||||
<DisplayName TxtId=""><![CDATA[{0}: Safetyinterlock reset timeout]]></DisplayName>
|
<DisplayName TxtId=""><![CDATA[{0}: Safetyinterlock reset timeout]]></DisplayName>
|
||||||
<Severity>Error</Severity>
|
<Severity>Error</Severity>
|
||||||
</EventId>
|
</EventId>
|
||||||
|
<EventId>
|
||||||
|
<Name Id="13">DCCBDidNotCloseInTime</Name>
|
||||||
|
<DisplayName TxtId=""><![CDATA[{} - DCCB could not be closed in time]]></DisplayName>
|
||||||
|
<Severity>Error</Severity>
|
||||||
|
</EventId>
|
||||||
<Hides>
|
<Hides>
|
||||||
<Hide GUID="{1D326C00-DF37-4B94-8E0D-C22524EB2E89}"/>
|
<Hide GUID="{1D326C00-DF37-4B94-8E0D-C22524EB2E89}"/>
|
||||||
<Hide GUID="{E7132508-795D-4A6C-AFB1-FED6C1DE44FD}"/>
|
<Hide GUID="{E7132508-795D-4A6C-AFB1-FED6C1DE44FD}"/>
|
||||||
@@ -148,6 +153,7 @@
|
|||||||
<Hide GUID="{E2F93DD0-9542-4F83-B1C1-7401F6E7E423}"/>
|
<Hide GUID="{E2F93DD0-9542-4F83-B1C1-7401F6E7E423}"/>
|
||||||
<Hide GUID="{F05A8F7C-1061-4AE4-AAAC-173C036FF4FC}"/>
|
<Hide GUID="{F05A8F7C-1061-4AE4-AAAC-173C036FF4FC}"/>
|
||||||
<Hide GUID="{99721C04-AF32-4BF0-BB6B-A59D0F9957F2}"/>
|
<Hide GUID="{99721C04-AF32-4BF0-BB6B-A59D0F9957F2}"/>
|
||||||
|
<Hide GUID="{4B5D56D2-4431-41C5-8F0A-06E1FC56151A}"/>
|
||||||
</Hides>
|
</Hides>
|
||||||
</DataType>
|
</DataType>
|
||||||
<DataType>
|
<DataType>
|
||||||
|
|||||||
@@ -18,7 +18,7 @@
|
|||||||
<EndAddress>11047</EndAddress>
|
<EndAddress>11047</EndAddress>
|
||||||
<VarName>GVL_MODBUS.stModbusEMSComm.stModbusReg11</VarName>
|
<VarName>GVL_MODBUS.stModbusEMSComm.stModbusReg11</VarName>
|
||||||
</MappingInfo>
|
</MappingInfo>
|
||||||
|
|
||||||
<!-- 12.000 Registers -->
|
<!-- 12.000 Registers -->
|
||||||
<MappingInfo>
|
<MappingInfo>
|
||||||
<AdsPort>851</AdsPort>
|
<AdsPort>851</AdsPort>
|
||||||
@@ -31,10 +31,11 @@
|
|||||||
<MappingInfo>
|
<MappingInfo>
|
||||||
<AdsPort>851</AdsPort>
|
<AdsPort>851</AdsPort>
|
||||||
<StartAddress>13000</StartAddress>
|
<StartAddress>13000</StartAddress>
|
||||||
<EndAddress>13004</EndAddress>
|
<EndAddress>13003</EndAddress>
|
||||||
<VarName>GVL_MODBUS.stBMSErrorReg</VarName>
|
<VarName>GVL_MODBUS.stBMSErrorReg.wBMSWarningActive</VarName>
|
||||||
</MappingInfo>
|
</MappingInfo>
|
||||||
|
|
||||||
|
|
||||||
<!-- 14.000 Registers -->
|
<!-- 14.000 Registers -->
|
||||||
<MappingInfo>
|
<MappingInfo>
|
||||||
<AdsPort>851</AdsPort>
|
<AdsPort>851</AdsPort>
|
||||||
@@ -50,6 +51,13 @@
|
|||||||
<EndAddress>15047</EndAddress>
|
<EndAddress>15047</EndAddress>
|
||||||
<VarName>GVL_MODBUS.awErrorsUnitsActive</VarName>
|
<VarName>GVL_MODBUS.awErrorsUnitsActive</VarName>
|
||||||
</MappingInfo>
|
</MappingInfo>
|
||||||
|
|
||||||
|
<MappingInfo>
|
||||||
|
<AdsPort>851</AdsPort>
|
||||||
|
<StartAddress>13004</StartAddress>
|
||||||
|
<EndAddress>13004</EndAddress>
|
||||||
|
<VarName>GVL_MODBUS.stBMSErrorReg.wConfirmAlarms</VarName>
|
||||||
|
</MappingInfo>
|
||||||
</OutputRegisters>
|
</OutputRegisters>
|
||||||
</Mapping>
|
</Mapping>
|
||||||
</Configuration>
|
</Configuration>
|
||||||
|
|||||||