diff --git a/.gitignore b/.gitignore index 1cf796a..1fb1b54 100644 --- a/.gitignore +++ b/.gitignore @@ -51,4 +51,7 @@ LineIDs.dbg.bak *.suo # Own Ignores -commit.txt \ No newline at end of file +commit.txt +*.txt +*.exe +*.xlsx \ No newline at end of file diff --git a/liste_alarme.md b/liste_alarme.md new file mode 100644 index 0000000..51227d0 --- /dev/null +++ b/liste_alarme.md @@ -0,0 +1,67 @@ +# List der Alarme + +Notiz: Die Aktuelle Schnittstelle ist noch nicht definiert, daher ist dies nur als Entwurf zu werten. + +## Kategorien + +Kat_1 -> Fehler +Kat_2 -> Manueller Eingriff +Kat_3 -> Warnung +Kat_4 -> Info Messages + + +## Liste Fehler + +- 1.01 {unit_descr}: Pressure difference segment inlet to big +- 1.02 {unit_descr}: DC main switch not closed +- 1.03 {unit_descr}: Leakage in double segment 1 and 2 +- 1.04 {unit_descr}: Leakage in double segment 3 and 4 +- 1.05 {unit_descr}: Leakage in tank +- 1.06 {unit_descr}: EtherCAT communication error +- 1.07 {unit_descr}: Isolation Error +- 1.08 {unit_descr}: Units out of balance +- 1.09 {unit_descr}: Modules out of balance +- 1.10 {unit_descr} Inverter startup timeout +- 1.11 Emergency stop not ok +- 1.12 {unit_descr}: EtherCAT communication error +- 1.13 {unit_descr}: Safetyinterlock reset timeout +- 1.14 {unit_descr} Inverter over temperature +- 1.15 {unit_descr} Inverter AC over voltage +- 1.16 {unit_descr} Inverter AC under voltage +- 1.17 {unit_descr} Inverter DC over voltage +- 1.18 {unit_descr} Inverter over frequency +- 1.19 {unit_descr} Inverter under frequency +- 1.20 {unit_descr} Inverter ground fault +- 1.21 {unit_descr} Inverter internal error +- 1.22 {unit_descr}: Inverter Error +- 1.23 Valve {unit_descr + sensor detail} did not open -> Bezogen auf valves +- 1.24 Valve {unit_descr + sensor detail} did not close -> Bezogen auf valves +- 1.25 Valve {unit_descr + sensor detail} feedback open circuit -> Bezogen auf valves +- 1.26 Valve {unit_descr + sensor detail} setpoint open circuit -> Bezogen auf valves +- 1.27 Valve {unit_descr + sensor detail} not in range +- 1.28 {unit_descr + sensor detail} input open circuit -> Bezogen auf Analog Input werte +- 1.29 Analog Input {unit_descr + sensor detail} card error +- 1.30 Analog Input {unit_descr + sensor detail} short circuit +- 1.31 Analog Input {unit_descr + sensor detail} configuration error +- 1.32 Analog Input {unit_descr + sensor detail}: Input Value below error limit ({limit}) +- 1.33 Analog Input {unit_descr + sensor detail}: Input Value above error limit ({1}) +- 1.34 Analog output {unit_descr + sensor detail} config error -> Bezogen auf Analog Output werte +- 1.35 Motor {unit_descr + sensor detail} repair switch open +- 1.36 Motor {unit_descr + sensor detail} not in target + +## Liste Manueller Eingriff + +- 2.01 Notaus {bereich} BetÃĪtigt + + +## List Warnungen +- 3.01 Not all components in automatic mode +- 3.02 {unit_descr}: Safetyinterlocks active +- 3.03 Analog Input {unit_descr + sensor detail}: Input Value below warning limit ({1}) +- 3.04 Analog Input {unit_descr + sensor detail}: Input Value above warning limit ({1}) + +## Liste Info Messages +- 4.01 Battery full +- 4.02 Battery empty +- 4.03 {unit_descr}: Shutdown discharge stopped because of low dc voltage +- 4.04 {unit_descr}: Shutdown discharge stopped because of unit voltage level