Added safety program pre comissioning and started implementing different modes
This commit is contained in:
@@ -21,12 +21,18 @@
|
||||
<Compile Include="DUTs\E_BATTERY_STATUS.TcDUT">
|
||||
<SubType>Code</SubType>
|
||||
</Compile>
|
||||
<Compile Include="DUTs\E_BMS_CONTROL_MODE.TcDUT">
|
||||
<SubType>Code</SubType>
|
||||
</Compile>
|
||||
<Compile Include="DUTs\E_CHARGE_STATUS.TcDUT">
|
||||
<SubType>Code</SubType>
|
||||
</Compile>
|
||||
<Compile Include="DUTs\E_REACTIVE_POWER_TYPE.TcDUT">
|
||||
<SubType>Code</SubType>
|
||||
</Compile>
|
||||
<Compile Include="DUTs\E_COMPONENT_STATUS.TcDUT">
|
||||
<SubType>Code</SubType>
|
||||
</Compile>
|
||||
<Compile Include="DUTs\Modbus\HoldingRegisters\ST_MODBUS_REG_10.TcDUT">
|
||||
<SubType>Code</SubType>
|
||||
</Compile>
|
||||
@@ -39,6 +45,9 @@
|
||||
<Compile Include="DUTs\Modbus\ST_EMS_MODBUS_INTERFACE.TcDUT">
|
||||
<SubType>Code</SubType>
|
||||
</Compile>
|
||||
<Compile Include="DUTs\ST_AUTO_HMI_INTERFACE.TcDUT">
|
||||
<SubType>Code</SubType>
|
||||
</Compile>
|
||||
<Compile Include="DUTs\ST_MODULE_HMI_INTERFACE.TcDUT">
|
||||
<SubType>Code</SubType>
|
||||
</Compile>
|
||||
@@ -114,21 +123,22 @@
|
||||
<DefaultResolution>Tc2_Standard, * (Beckhoff Automation GmbH)</DefaultResolution>
|
||||
<Namespace>Tc2_Standard</Namespace>
|
||||
</PlaceholderReference>
|
||||
<PlaceholderReference Include="Tc2_SUPS">
|
||||
<DefaultResolution>Tc2_SUPS, * (Beckhoff Automation GmbH)</DefaultResolution>
|
||||
<Namespace>Tc2_SUPS</Namespace>
|
||||
</PlaceholderReference>
|
||||
<PlaceholderReference Include="Tc2_System">
|
||||
<DefaultResolution>Tc2_System, * (Beckhoff Automation GmbH)</DefaultResolution>
|
||||
<Namespace>Tc2_System</Namespace>
|
||||
</PlaceholderReference>
|
||||
<PlaceholderReference Include="Tc2_Utilities">
|
||||
<DefaultResolution>Tc2_Utilities, * (Beckhoff Automation GmbH)</DefaultResolution>
|
||||
<Namespace>Tc2_Utilities</Namespace>
|
||||
</PlaceholderReference>
|
||||
<PlaceholderReference Include="Tc3_EventLogger">
|
||||
<DefaultResolution>Tc3_EventLogger, * (Beckhoff Automation GmbH)</DefaultResolution>
|
||||
<Namespace>Tc3_EventLogger</Namespace>
|
||||
</PlaceholderReference>
|
||||
<PlaceholderReference Include="Tc3_IotBase">
|
||||
<DefaultResolution>Tc3_IotBase, * (Beckhoff Automation GmbH)</DefaultResolution>
|
||||
<Namespace>Tc3_IotBase</Namespace>
|
||||
</PlaceholderReference>
|
||||
<PlaceholderReference Include="Tc3_Module">
|
||||
<DefaultResolution>Tc3_Module, * (Beckhoff Automation GmbH)</DefaultResolution>
|
||||
<Namespace>Tc3_Module</Namespace>
|
||||
@@ -139,6 +149,11 @@
|
||||
<SubType>Content</SubType>
|
||||
</None>
|
||||
</ItemGroup>
|
||||
<ItemGroup>
|
||||
<PlaceholderResolution Include="BaseLib">
|
||||
<Resolution>BaseLib, * (cmblu)</Resolution>
|
||||
</PlaceholderResolution>
|
||||
</ItemGroup>
|
||||
<ProjectExtensions>
|
||||
<PlcProjectOptions>
|
||||
<XmlArchive>
|
||||
|
||||
Reference in New Issue
Block a user