<Declaration><![CDATA[FUNCTION_BLOCK FB_Unit
VAR_INPUT
// Unit configuration
stUnitConfig : REFERENCE TO ST_UNIT_CONFIG;
// HMI interface
stHMIInterface : REFERENCE TO ST_UNIT_HMI_INTERFACE;
// Start unit
xEnable : BOOL;
// Emergency stop ok
xEmergencyStopOk : BOOL;
// Setpoint posolyt pump inlet
rSetpointPosolytPumpInlet : REAL;
// Setpoint negolyt pump inlet
rSetpointNegolytPumpInlet : REAL;
// Release alarms
xReleaseErrors : BOOL;
// Release analog io limit errors
xReleaseLimitErrors : BOOL;
// Input to confirm all errors
xConfirmAlarms : BOOL;
END_VAR
VAR_OUTPUT
// Unit ready
xReady : BOOL;
// Error active
xError : BOOL;
// Warning active
xWarning : BOOL;
// Warning confirmation still pending
_xWarningConfirmPending : BOOL;
END_VAR
VAR
// Check unit condition after some time during startup
_timUnitStartupWaitTime : TIME := T#20S;
// Valves posolyt
_fbPosolytValveTankOutlet : FB_Valve('Posolyt tank outlet');
// Valves negolyt
_fbNegolytValveTankOutlet : FB_Valve('Negolyt tank outlet');
// Pumps posolyt
_fbPosolytPumpInlet : FB_MotorAnalog('Posolyt segment inlet');
// Pumps negolyt
_fbNegolytPumpInlet : FB_MotorAnalog('Negolyt segment inlet');
// Pressure sensors posolyt
_fbPressurePosolytSegmentInlet : FB_AnalogInput('P1_P');
_fbPressurePosolytTankInlet : FB_AnalogInput('P3_P');
_fbPressurePosolytTankOutlet : FB_AnalogInput('P4_P');
// Pressure sensors negolyt
_fbPressureNegolytSegmentInlet : FB_AnalogInput('P1_N');
_fbPressureNegolytTankInlet : FB_AnalogInput('P3_N');
_fbPressureNegolytTankOutlet : FB_AnalogInput('P4_N');
// Unit voltage
_fbVoltageSegment : FB_AnalogInput('Voltage');
// Valve posolyt tank outlet interlocks
_stPosolytValveTankOutletPIntlk : T_INTERLOCK;
_stPosolytValveTankOutletPIntlkUsed : T_INTERLOCK := 2#0000_0000_0000_0000;
_stPosolytValveTankOutletSIntlk : T_INTERLOCK;
_stPosolytValveTankOutletSIntlkUsed : T_INTERLOCK := 2#0000_0000_0000_0011;
// Valve negolyt tank outlet interlocks
_stNegolytValveTankOutletPIntlk : T_INTERLOCK;
_stNegolytValveTankOutletPIntlkUsed : T_INTERLOCK := 2#0000_0000_0000_0000;
_stNegolytValveTankOutletSIntlk : T_INTERLOCK;
_stNegolytValveTankOutletSIntlkUsed : T_INTERLOCK := 2#0000_0000_0000_0011;
// Pump posolyt inlet interlocks
_stPosolytPumpInletPIntlk : T_INTERLOCK;
_stPosolytPumpInletPIntlkUsed : T_INTERLOCK := 2#0000_0000_0000_0001;
_stPosolytPumpInletSIntlk : T_INTERLOCK;
_stPosolytPumpInletSIntlkUsed : T_INTERLOCK := 2#0000_0000_0000_0011;
// Pump negolyt inlet interlocks
_stNegolytPumpInletPIntlk : T_INTERLOCK;
_stNegolytPumpInletPIntlkUsed : T_INTERLOCK := 2#0000_0000_0000_0001;
_stNegolytPumpInletSIntlk : T_INTERLOCK;
_stNegolytPumpInletSIntlkUsed : T_INTERLOCK := 2#0000_0000_0000_0011;
// Error active
_xErrorActive : BOOL;
// Warning active
_xWarningActive : BOOL;
// Current state
_iState: INT;
// All components in automatic mode
_xAllComponentsInAutomatic : BOOL;
// Not all components in automatic mode alarm
_fbNotAllAutomaticAlarm : FB_TcAlarm;
// Unit name
_sName : STRING;
// Unit startup check timer
_tonStartupCheck : TON;
END_VAR
]]></Declaration>
<Implementation>
<ST><![CDATA[// Reset error active
_xErrorActive := FALSE;
// Reset warning active
_xWarningActive := FALSE;
// ===============================
// Valve posolyt tank outlet
// ===============================
// Safety Interlocks
stHMIInterface.stPosolytValve.stInterlock.asSafetyINTLKName[0] := 'Emergency stop ok';
_stPosolytValveTankOutletSIntlk.0 := xEmergencyStopOk;
// Valve fb
_fbPosolytValveTankOutlet(
xReleaseManualMode:= TRUE,
wProcessINTLK:= _stPosolytValveTankOutletPIntlk,
wProcessINTLKUsed:= _stPosolytValveTankOutletPIntlkUsed,
wSafetyINTLK:= _stPosolytValveTankOutletSIntlk,
wSafetyINTLKUsed:= _stPosolytValveTankOutletSIntlkUsed,
xConfirmAlarms:= xConfirmAlarms,
xReleaseErrors:= xReleaseErrors,
stValveConfig:= stUnitConfig.stConfigPosolytValve,
stHMIInterface:= stHMIInterface.stPosolytValve);
// Set error active if fb has error
IF _fbPosolytValveTankOutlet.xError THEN
_xErrorActive := TRUE;
END_IF
// ===============================
// Valve negolyt tank outlet
// ===============================
// Safety Interlocks
stHMIInterface.stNegolytValve.stInterlock.asSafetyINTLKName[0] := 'Emergency stop ok';
_stNegolytValveTankOutletSIntlk.0 := xEmergencyStopOk;
// Valve fb
_fbNegolytValveTankOutlet(
xReleaseManualMode:= TRUE,
wProcessINTLK:= _stNegolytValveTankOutletPIntlk,
wProcessINTLKUsed:= _stNegolytValveTankOutletPIntlkUsed,
wSafetyINTLK:= _stNegolytValveTankOutletSIntlk,
wSafetyINTLKUsed:= _stNegolytValveTankOutletSIntlkUsed,
xConfirmAlarms:= xConfirmAlarms,
xReleaseErrors:= xReleaseErrors,
stValveConfig:= stUnitConfig.stConfigNegolytValve,
stHMIInterface:= stHMIInterface.stNegolytValve);
// Set error active if fb has error
IF _fbNegolytValveTankOutlet.xError THEN
_xErrorActive := TRUE;
END_IF
// ===============================
// Pump posolyt segment inlet
// ===============================
// Safety Interlocks
stHMIInterface.stPosolytPump.stInterlock.asSafetyINTLKName[0] := 'Emergency stop ok';
_stPosolytPumpInletSIntlk.0 := xEmergencyStopOk;
// Process interlocks
stHMIInterface.stPosolytPump.stInterlock.asProcessINTLKName[0] := 'At least one valve is open';
_stPosolytPumpInletPIntlk.0 := _fbPosolytValveTankOutlet.IsOpen;
// Valve fb
_fbPosolytPumpInlet(
xReleaseManualMode:= TRUE,
wProcessINTLK:= _stPosolytPumpInletPIntlk,
wProcessINTLKUsed:= _stPosolytPumpInletPIntlkUsed,
wSafetyINTLK:= _stPosolytPumpInletSIntlk,
wSafetyINTLKUsed:= _stPosolytPumpInletSIntlkUsed,
xReleaseErrors:= xReleaseErrors,
xConfirmAlarms:= xConfirmAlarms,
rSPautomatic:= rSetpointPosolytPumpInlet,
xReleaseAnalogInLimitErrors:= xReleaseLimitErrors,
stMotorAnalogConfig:= stUnitConfig.stConfigPosolytPump,
stHMIInterface:= stHMIInterface.stPosolytPump,
xWarning=> );
// Set error active if fb has error
IF _fbPosolytPumpInlet.xError THEN
_xErrorActive := TRUE;
END_IF
// Set warning if fb has warning
IF _fbPosolytPumpInlet.xWarning THEN
_xWarningActive := TRUE;
END_IF
// ===============================
// Pump negolyt segment inlet
// ===============================
// Safety Interlocks
stHMIInterface.stNegolytPump.stInterlock.asSafetyINTLKName[0] := 'Emergency stop ok';
_stNegolytPumpInletSIntlk.0 := xEmergencyStopOk;
// Process interlocks
stHMIInterface.stNegolytPump.stInterlock.asProcessINTLKName[0] := 'At least one valve is open';
_stNegolytPumpInletPIntlk.0 := _fbNegolytValveTankOutlet.IsOpen;
// Valve fb
_fbNegolytPumpInlet(
xReleaseManualMode:= TRUE,
wProcessINTLK:= _stNegolytPumpInletPIntlk,
wProcessINTLKUsed:= _stNegolytPumpInletPIntlkUsed,
wSafetyINTLK:= _stNegolytPumpInletSIntlk,
wSafetyINTLKUsed:= _stNegolytPumpInletSIntlkUsed,
xReleaseErrors:= xReleaseErrors,
xConfirmAlarms:= xConfirmAlarms,
rSPautomatic:= rSetpointNegolytPumpInlet,
xReleaseAnalogInLimitErrors:= xReleaseLimitErrors,
stMotorAnalogConfig:= stUnitConfig.stConfigNegolytPump,
stHMIInterface:= stHMIInterface.stNegolytPump,
xWarning=> );
// Set error active if fb has error
IF _fbNegolytPumpInlet.xError THEN
_xErrorActive := TRUE;
END_IF
// Set warning if fb has warning
IF _fbNegolytPumpInlet.xWarning THEN
_xWarningActive := TRUE;
END_IF
// ===============================
// Pressure sensors posolyt segment inlet
// ===============================
_fbPressurePosolytSegmentInlet(
stScalingConfig:= stUnitConfig.stConfigPosolytPressureSegmentInlet,
stEWConfig:= stUnitConfig.stEWLPosolytPressureSegmentInlet,
stEWDelayConfig:= stUnitConfig.stEWDPosolytPressureSegmentInlet,
xReleaseErrors:= xReleaseErrors,
xReleaseLimitErrors:= xReleaseLimitErrors,
xReleaseHardwareErrors:= xReleaseErrors,
xConfirmAlarms:= xConfirmAlarms,
stHMIInterface => stHMIInterface.stPosolytPressureSegmentInlet);
// Set error active if fb has error
IF _fbPressurePosolytSegmentInlet.xError THEN
_xErrorActive := TRUE;
END_IF
// Set warning if fb has warning
IF _fbPressurePosolytSegmentInlet.xWarning THEN
_xWarningActive := TRUE;
END_IF
// ===============================
// Pressure sensors negolyt segment inlet
// ===============================
_fbPressureNegolytSegmentInlet(
stScalingConfig:= stUnitConfig.stConfigNegolytPressureSegmentInlet,
stEWConfig:= stUnitConfig.stEWLNegolytPressureSegmentInlet,
stEWDelayConfig:= stUnitConfig.stEWDNegolytPressureSegmentInlet,
xReleaseErrors:= xReleaseErrors,
xReleaseLimitErrors:= xReleaseLimitErrors,
xReleaseHardwareErrors:= xReleaseErrors,
xConfirmAlarms:= xConfirmAlarms,
stHMIInterface => stHMIInterface.stNegolytPressureSegmentInlet);
// Set error active if fb has error
IF _fbPressureNegolytSegmentInlet.xError THEN
_xErrorActive := TRUE;
END_IF
// Set warning if fb has warning
IF _fbPressureNegolytSegmentInlet.xWarning THEN
_xWarningActive := TRUE;
END_IF
// ===============================
// Voltage segment
// ===============================
_fbVoltageSegment(
stScalingConfig:= ,
stEWConfig:= ,
stEWDelayConfig:= ,
xReleaseErrors:= xReleaseErrors,
xReleaseLimitErrors:= xReleaseLimitErrors,
xReleaseHardwareErrors:= xReleaseErrors,
xConfirmAlarms:= xConfirmAlarms,
stHMIInterface=> stHMIInterface.stVoltageSegment);
// Set error active if fb has error
IF _fbVoltageSegment.xError THEN
_xErrorActive := TRUE;
END_IF
// Set warning if fb has warning
IF _fbVoltageSegment.xWarning THEN
_xWarningActive := TRUE;
END_IF
// ===============================
// Check if all components are in automatic
// ===============================
_xAllComponentsInAutomatic := _fbPosolytValveTankOutlet.IsInAutomaticMode
AND _fbNegolytValveTankOutlet.IsInAutomaticMode
AND _fbPosolytPumpInlet.IsInAutomaticMode
AND _fbNegolytPumpInlet.IsInAutomaticMode;
// Raise warning
IF NOT _fbNotAllAutomaticAlarm.bRaised AND (NOT _xAllComponentsInAutomatic) THEN
_fbNotAllAutomaticAlarm.Raise(0);
END_IF
// Clear warning and reset
IF _fbNotAllAutomaticAlarm.bRaised AND _xAllComponentsInAutomatic THEN
_fbNotAllAutomaticAlarm.Clear(0, TRUE);
END_IF
// ===============================
// Run state machine for startup and shutdown
// ===============================
CASE _iState OF
0: // Off
IF xEnable AND _xAllComponentsInAutomatic AND (NOT _xErrorActive) THEN
_iState := 10;
END_IF
10: // Open all valves
_fbPosolytValveTankOutlet.ReqAutomaticOpen();
_fbNegolytValveTankOutlet.ReqAutomaticOpen();
_iState := 15;
15: // Wait for all valves to be open
IF _fbPosolytValveTankOutlet.IsOpen AND _fbNegolytValveTankOutlet.IsOpen THEN
IF NOT _fbPosolytValveTankOutlet.xError AND _fbNegolytValveTankOutlet.xError THEN
_iState := 20;
END_IF
END_IF
// If enable signal is lost, or there is an error, goto shutdown
IF (NOT xEnable) OR _xErrorActive THEN
_iState := 40;
END_IF
20: // Start pumps
_fbPosolytPumpInlet.ReqAutomaticStart();
_fbNegolytPumpInlet.ReqAutomaticStart();
_iState := 25;
25: // Wait for all pumps to run
IF _fbPosolytPumpInlet.xInTarget AND _fbNegolytPumpInlet.xInTarget THEN
_iState := 30;
END_IF
// If enable signal is lost, goto shutdown
IF (NOT xEnable) OR _xErrorActive THEN
_iState := 40;
END_IF
30: // Wait some time
_tonStartupCheck(In := TRUE, PT := _timUnitStartupWaitTime);
// After some time, check if all values are ok
IF _tonStartupCheck.Q THEN
// Check for minimum unit voltage
IF _fbVoltageSegment.rScaledValue >= GVL_CONFIG.rMinimumUnitVoltage AND
NOT _xErrorActive AND
NOT _xWarningActive THEN
xReady := TRUE;
_iState := 35;
ELSE
_iState := 40;
END_IF
END_IF
// If enable signal is lost, goto shutdown
IF (NOT xEnable) OR _xErrorActive THEN
_iState := 40;
END_IF
35: // Unit in enabled state
IF (NOT xEnable) OR _xErrorActive THEN
_iState := 40;
END_IF
40: // Close all valves
_fbNegolytValveTankOutlet.ReqAutomaticClose();
_fbPosolytValveTankOutlet.ReqAutomaticClose();
_iState := 45;
45: // Wait for valves to be closed
IF _fbNegolytValveTankOutlet.IsClosed AND _fbPosolytValveTankOutlet.IsClosed THEN
_iState := 50;
END_IF
// When there is an error trying to close the valves,
// dont try to discharge the segment
IF _fbNegolytValveTankOutlet.xError OR _fbPosolytValveTankOutlet.xError THEN
_iState := 60;
END_IF
// Check for restart condition
IF xEnable AND (NOT _xErrorActive) THEN
_iState := 0;
END_IF
50: // Wait for unit voltage to drop below a certain threshold
IF (_fbVoltageSegment.rScaledValue <= GVL_CONFIG.rPumpshutoffThreshold) THEN
_iState := 60;
END_IF
// Check for restart condition
IF xEnable AND (NOT _xErrorActive) THEN
_iState := 0;
END_IF
60: // Disable pumps
_fbPosolytPumpInlet.ReqAutomaticStop();
_fbNegolytPumpInlet.ReqAutomaticStop();
_iState := 65;
65: // Wait for pumps to be stopped
IF _fbPosolytPumpInlet.IsStopped AND _fbNegolytPumpInlet.IsStopped THEN
IF _xErrorActive THEN
_iState := 1000;
ELSE
_iState := 0;
END_IF
END_IF
// Check for restart condition
IF xEnable AND (NOT _xErrorActive) THEN
_iState := 0;
END_IF
1000: // Alarm active
// Only allow reset when enable is deactivated to avoid an
// automatic restart of the unit
IF (NOT _xErrorActive) AND (NOT xEnable) THEN
_iState := 0;
END_IF
END_CASE
// ===============================
// Output error and warning flags
// ===============================
xError := _xErrorActive;
xWarning := _xWarningActive;]]></ST>
</Implementation>
<Method Name="FB_init" Id="{08f1cd44-6483-4d20-ab45-d1938e8ec885}">
<Declaration><![CDATA[METHOD FB_init : BOOL
VAR_INPUT
bInitRetains : BOOL; // if TRUE, the retain variables are initialized (warm start / cold start)
bInCopyCode : BOOL; // if TRUE, the instance afterwards gets moved into the copy code (online change)
sName : STRING;
END_VAR
]]></Declaration>
<Implementation>
<ST><![CDATA[_sName := sName;
_fbNotAllAutomaticAlarm.CreateEx(TC_EVENTS.General.NotAllCompInAutomatic, bWithConfirmation := FALSE, 0);
_fbNotAllAutomaticAlarm.ipArguments.Clear().AddString(_sName);]]></ST>
</Implementation>
</Method>
<LineIds Name="FB_Unit">
<LineId Id="4232" Count="29" />
<LineId Id="4584" Count="0" />
<LineId Id="4263" Count="102" />
<LineId Id="4619" Count="0" />
<LineId Id="4367" Count="46" />
<LineId Id="4621" Count="22" />
<LineId Id="4620" Count="0" />
<LineId Id="4644" Count="1" />
<LineId Id="4414" Count="0" />
<LineId Id="4647" Count="0" />
<LineId Id="4646" Count="0" />
<LineId Id="4416" Count="17" />
<LineId Id="4444" Count="26" />
<LineId Id="4476" Count="33" />
<LineId Id="4511" Count="17" />
<LineId Id="4653" Count="0" />
<LineId Id="4655" Count="2" />
<LineId Id="4654" Count="0" />
<LineId Id="4529" Count="4" />
<LineId Id="4658" Count="0" />
<LineId Id="4660" Count="2" />
<LineId Id="4659" Count="0" />
<LineId Id="4569" Count="0" />
<LineId Id="4535" Count="12" />
<LineId Id="4663" Count="0" />
<LineId Id="4665" Count="2" />
<LineId Id="4664" Count="0" />
<LineId Id="4548" Count="6" />
<LineId Id="4556" Count="6" />
<LineId Id="2754" Count="0" />
</LineIds>
<LineIds Name="FB_Unit.FB_init">
<LineId Id="11" Count="1" />
<LineId Id="7" Count="1" />
</LineIds>
</POU>
</TcPlcObject>