Files
infineon_plc/Packages/Beckhoff.TwinCAT.HMI.Server.Engineering.22.0.7563/runtimes/win-x64/native/TcHmiSqliteLogger/TcHmiSqliteLogger.Language.en.json
m.heisig 2d11c43579 Added minimal functionality for Robot teaching
- Added minimal HMI
- Added possibility to open and close all chamber doors
2026-01-17 09:20:39 +01:00

43 lines
2.5 KiB
JSON

{
"locale": "en",
"localizedText": {
"MAXENTRIES": "Maximum number of entries",
"DESC_MAXENTRIES": "To limit the database size, the oldest database entries are permanently deleted when this limit is exceeded.",
"MAXENTRYLENGTH": "Maximum length of an entry",
"DESC_MAXENTRYLENGTH": "Entries that exceed this limit will be truncated before being stored.",
"EVENTREQUIRESCONFIRMATION": "Event {0} requires confirmation",
"EVENTCONFIRMED": "Event {0} got confirmed",
"DEFAULT_LIST_LIMIT": "Default limit for entry lists",
"DESC_DEFAULT_LIST_LIMIT": "This limit is used for all requests for which no other limit has been specified.",
"VACUUM_ON_STARTUP": "Vacuum at startup",
"DESC_VACUUM_ON_STARTUP": "Tries to reduce database size. This might take a while on big databases.",
"MODE": "Mode",
"DESC_MODE": "Synchronous off mode is fast but can corrupt the database in case of a power failure.",
"ENUM_SYNCHRONOUS_EXTRA_PERSIST": "Synchronous extra",
"ENUM_SYNCHRONOUS_FULL_PERSIST": "Synchronous full",
"ENUM_SYNCHRONOUS_NORMAL_PERSIST": "Synchronous normal",
"ENUM_SYNCHRONOUS_OFF_PERSIST": "Synchronous off",
"REDIRECT_DIAGNOSTICS_MESSAGES_TO_FILE": "Redirect diagnostics messages to file",
"DESC_REDIRECT_DIAGNOSTICS_MESSAGES_TO_FILE": "Reduces the chance that a flood of diagnostics messages will overwhelm the system. Especially useful when diagnosing problems on smaller devices. Only supported on Windows. Server restart required.",
"REDIRECTING_DIAGNOSTICS_MESSAGES_TO_FILE": "Redirecting diagnostics messages to this file: {0}",
"MAX_DIAGNOSTICS_MESSAGES_FILE_SIZE": "Maximum size of the file containing the diagnostic messages",
"MAX_DIAGNOSTICS_ARCHIVE_FILE_COUNT": "Maximum count of archive files containing diagnostic messages",
"DESC_MAX_DIAGNOSTICS_MESSAGES_FILE_SIZE": "Server restart required.",
"DESC_MAX_DIAGNOSTICS_ARCHIVE_FILE_COUNT": "Server restart required.",
"MSG_SHUTDOWN": "Shutdown extension {0} succeeded.",
"allDomains": "All domains",
"perDomain": "Per domain",
"databaseSize": "Database size",
"persistentDatabaseSize": "Size of the persistent database",
"numEvents": "Number of events",
"numPersistentEvents": "Number of persistent events",
"numEventsWithAlarmPayload": "Number of alarms",
"numPersistentEventsWithAlarmPayload": "Number of persistent alarms",
"numEventsWithMessagePayload": "Number of messages",
"numPersistentEventsWithMessagePayload": "Number of persistent messages"
}
}