Files
infineon_plc/PLC/01_Stationen/Aligner/FB_Aligner.TcPOU
m.heisig bdaaf1fe9f Fixed aligner and started main state machine
- Fixed datatype for received offsets
- Added HMI Interface for Hot and Coolplate
2026-02-06 14:39:41 +01:00

73 lines
1.8 KiB
XML

<?xml version="1.0" encoding="utf-8"?>
<TcPlcObject Version="1.1.0.1">
<POU Name="FB_Aligner" Id="{5be6cab7-2294-48e5-869c-33773329143e}" SpecialFunc="None">
<Declaration><![CDATA[FUNCTION_BLOCK FB_Aligner EXTENDS FB_PackMLGeneric
VAR_INPUT
xEnableVacuum : BOOL;
xAlign : BOOL;
xConfirmAlarms : BOOL;
END_VAR
VAR_OUTPUT
xVacuumEnabled : BOOL;
END_VAR
VAR
_fbXAxis : FB_AxisPTP;
_fbYAxis : FB_AxisPTP;
_xEnableVacuum AT %Q* : BOOL := FALSE;
_xDisableVacuum AT %Q* : BOOL := TRUE;
_xVacuumOk AT %I* : BOOL;
_udiXOffset AT %I* : DINT;
_udiYOffset AT %I* : DINT;
_rXPosToGo : REAL;
_rYPosToGo : REAL;
END_VAR
]]></Declaration>
<Implementation>
<ST><![CDATA[_fbXAxis(
xEnable:= TRUE,
xInvertCalibrationCam:= FALSE,
xEnablePositive:= TRUE,
xEnableNegative:= TRUE,
rOverride:= 100.0,
lrVelocity:= 2.5,
lrAcceleration:= 0,
lrDecelleration:= 0,
lrJerk:= 0,
xConfirmAlarms:= xConfirmAlarms);
_fbYAxis(
xEnable:= TRUE,
xInvertCalibrationCam:= FALSE,
xEnablePositive:= TRUE,
xEnableNegative:= TRUE,
rOverride:= 100.0,
lrVelocity:= 2.5,
lrAcceleration:= 0,
lrDecelleration:= 0,
lrJerk:= 0,
xConfirmAlarms:= xConfirmAlarms);
// Drei mal ausführen damit die Position genau ist
IF xAlign THEN
xAlign := FALSE;
_rXPosToGo := DINT_TO_REAL(_udiXOffset) * -0.001;
_rYPosToGo := ((DINT_TO_REAL(_udiYOffset) * 0.001) - 37.5) * -1;
IF (ABS(_rXPosToGo) < 10.0) AND (ABS(_rYPosToGo) < 10.0) AND (NOT _fbXAxis.xError) AND (NOT _fbYAxis.xError) THEN
_fbXAxis.M_MoveRel(lrRelDist := _rXPosToGo);
_fbYAxis.M_MoveRel(lrRelDist := _rYPosToGo);
END_IF
END_IF
// Handle enable disable vacuum command
_xEnableVacuum := xEnableVacuum;
_xDisableVacuum := (NOT xEnableVacuum);
xVacuumEnabled := _xVacuumOk;]]></ST>
</Implementation>
</POU>
</TcPlcObject>