Author SHA1 Message Date
Matthias Heisig
2d65d0b3db Last changes before SAT 2025-10-14 16:19:19 +02:00
Matthias Heisig
eaaa2371e8 Change E-Stop so that it can also work with one string
- Also optimized CV charging
2025-10-07 16:23:37 +02:00
Matthias Heisig
14ec270259 Fixed modbus interface
- Changed registerdefinition in modbus server because or single register reading
2025-10-06 14:40:45 +02:00
Matthias Heisig
27848d6acc Repaired Project file
- Added controller back to project file. Got missing during last commit
2025-10-01 10:58:09 +02:00
Matthias Heisig
698451cc1f Some bugfixes
- Config for max string power is now correctly calculated
- Adjusted timing for string and inverter timeout
2025-09-29 11:38:43 +02:00
Matthias Heisig
dd82744356 Fixed some bugs and added inverter status to modbus register
- Safety now has a tof of 0,5s for Temp, Voltage and Pressure
- Doppelhöcker now switches powercommand during second phase
2025-09-24 10:10:37 +02:00
Matthias Heisig
0d3369d54d Added error and waring messages and updated tower light inputs
- Added strings not ready in time error
- Added battery already full warning
- Added battery already empty warning
- Added battery in stop input to tower light
- Added warnings active to tower light
- Added BMS State Machine errors to tower light input
2025-09-10 12:13:40 +02:00
Markus.Neukirch
39a206a1df Fixed startup time reset error in balancing mode 2025-09-09 12:28:22 +02:00
Markus.Neukirch
f0e6143997 IBN changes
added sync units for cabinet temperature, changes in modbus interface to EMS (1.0.4 and 1.0.5), added error counter to modbus communication, lot of changes to kaco (faults, consecutive errors, bms error messages), isolation error ledge, allowed startbalancing when on shutdown, tower light integration
2025-09-05 14:24:37 +02:00
Matthias Heisig
9c6e28b83d Added Kaco inverter implementation
- Added Kaco inverter implementation
- Small refactoring
- Added release inverter power signal for simultaneous start of the
  inverters
2025-08-11 23:26:40 +09:00
Matthias Heisig
38f44128d1 Added precharge mode 2025-06-04 19:37:25 +02:00
Matthias Heisig
2f9f4df261 changes during start of safety check
- Refactoring of string fb
- Added pump safety interlocks for pressure segment inlet too low and too high
2025-06-02 19:51:57 +02:00
Matthias Heisig
1677d34d9c Added Kaco inverter for sensor ripple testing
- Iso error in string will now only be active if the dc circuit breaker is not closed
- Added some delay between closing dc circuit breaker and enabling inverter so that the dc bus voltage can stabilize itself
2025-05-08 10:07:16 +02:00
Matthias Heisig
94381dc704 Changed Safety program so that every group can be deactivated 2025-04-28 17:15:43 +02:00
Matthias Heisig
f79cf27c0c Finished first implementation of modbus error registers 2025-04-14 19:38:17 +02:00
Matthias Heisig
4a00a4c414 Added Modbus registers 2025-04-08 07:24:55 +02:00
Matthias Heisig
2221f6bab3 Minor bugfixes and future addons 2025-04-06 10:21:01 +02:00
Matthias Heisig
2ded890dd4 Added multi string handling and balancing 2025-02-13 21:26:50 +01:00
Matthias Heisig
0345f57a3f Some refactoring 2025-01-17 08:08:37 +01:00
Matthias Heisig
5e94ba4868 Merge branch 'feature/ManualModeSwitch' into develop
# Conflicts:
#	PLC/PLC.tmc
#	PLC/POUs/FB_String.TcPOU
#	PLC/POUs/MAIN.TcPOU
#	Uniper.tsproj
2024-08-30 14:32:11 +02:00
Matthias Heisig
08d2ffd136 Added string startup timeout 2024-08-30 13:12:42 +02:00
Matthias Heisig
112f7cb7d9 Added automatic manual mode change for all components if manual mode is selected, Added moving average filter to analog data 2024-08-26 22:19:29 +02:00
Matthias Heisig
0d9a4d9c72 WIP: Aktueller stand für fehlersuche Sensorrauschen 2024-05-22 17:43:26 +02:00
Matthias Heisig
0ffff9be2a EMS communication and Voltage optimizations
- Added data for EMS communication
- Added highest segment voltage for charging check
- Added lowest segment voltage for discharging check
2024-05-07 17:10:29 +02:00
Matthias Heisig
327f324be8 Implemented fixes and improvements during comissioning
- New Balancing mode
- HMI Interface for Inverterdata implemented
- Adjusted GVL_CONFIG values
- Read inverter data even when inverter is off
- Added OPC UA settings to inverter data hmi interface
- Added multisettings to safety project for strings
2024-05-06 11:05:33 +02:00
Matthias Heisig
b95033a155 First string implemented 2024-04-18 08:32:21 +02:00
Matthias Heisig
9ce3522a70 WIP: Inbetriebnahme vorladen 2024-04-11 19:06:45 +02:00
Matthias Heisig
ef26159a4f Added safety program pre comissioning and started implementing different modes 2024-03-20 18:08:57 +01:00
Matthias Heisig
57987cb19f Fixed Modbus register access 2024-01-17 11:26:11 +01:00
Matthias Heisig
faa33db290 Projektdateien hinzufügen. 2024-01-04 15:15:26 +01:00