Some improvements and fixes
- Added robot schift params for aligning etcher 1 position - Added HMI Interface to robot fb - Added machine LED's at main cabinet - Aligner now works in auto mode - Added HMI interface to etcher station - Added cReleaseAlarms to HeatCoolPlates - Added HMI interface to HVTester - STarted tray feeder response parsing - Fixed some packml base state machine bugs
This commit is contained in:
@@ -3,6 +3,7 @@
|
||||
<POU Name="FB_HeatCoolPlates" Id="{a2be063c-19d7-4ca2-8121-529d61cc7bc2}" SpecialFunc="None">
|
||||
<Declaration><![CDATA[FUNCTION_BLOCK FB_HeatCoolPlates
|
||||
VAR_INPUT
|
||||
xReleaseAlarms : BOOL;
|
||||
xConfirmAlarms : BOOL;
|
||||
END_VAR
|
||||
VAR_OUTPUT
|
||||
@@ -25,6 +26,7 @@ END_VAR
|
||||
xEnable:= _xEnableHotplate,
|
||||
rTargetTemp:= _rTargetTemp,
|
||||
stHMIInterface := stHMIInterface.stHotplateHMIInterface,
|
||||
xReleaseAlarms := xReleaseAlarms,
|
||||
xConfirmAlarms:= xConfirmAlarms,
|
||||
uiNextFreeSlot=> ,
|
||||
uiNextReadySlot=> );
|
||||
|
||||
@@ -6,6 +6,7 @@ VAR_INPUT
|
||||
xEnable : BOOL;
|
||||
rTargetTemp : REAL;
|
||||
|
||||
xReleaseAlarms : BOOL;
|
||||
xConfirmAlarms : BOOL;
|
||||
END_VAR
|
||||
VAR_OUTPUT
|
||||
@@ -47,7 +48,7 @@ END_VAR
|
||||
_fbTempSensor(
|
||||
stAnalogIOConfig:= _stTempSensorConfig,
|
||||
stAnalogEWConfig:= _stTempSEnsorEWConfig,
|
||||
xReleaseErrors:= TRUE,
|
||||
xReleaseErrors:= xReleaseAlarms,
|
||||
xReleaseLimitErrors:= FALSE,
|
||||
xReleaseHardwareErrors:= TRUE,
|
||||
xConfirmAlarms:= xConfirmAlarms,
|
||||
@@ -79,7 +80,7 @@ _fbLimit(
|
||||
xClampedLower=> _fbPITempControl.xSaturatedLower);
|
||||
|
||||
_fbPWMOut(
|
||||
timPeriod:= T#10S,
|
||||
timPeriod:= T#100MS,
|
||||
xOutput=> xEnableHotplate);
|
||||
|
||||