Files
infineon_plc/PLC/00_Main/PRG_Safety.TcPOU
m.heisig 1ade81c1c5 Added hot and cold plates
- Started spinner chuck io's
2026-02-01 13:53:21 +01:00

41 lines
987 B
XML

<?xml version="1.0" encoding="utf-8"?>
<TcPlcObject Version="1.1.0.1">
<POU Name="PRG_Safety" Id="{3b12eabc-3e96-45aa-8279-75f07072b9b0}" SpecialFunc="None">
<Declaration><![CDATA[PROGRAM PRG_Safety
VAR_INPUT
xConfirmAlarms : BOOL;
xRobotStopped : BOOL;
END_VAR
VAR_OUTPUT
xStopRobot : BOOL := FALSE;
END_VAR
VAR
_xRun AT %Q* : BOOL;
_xEStopOk AT %I* : BOOL;
_xRequestOpenDoor AT %I* : BOOL;
_rtrigDoorUnlock : R_TRIG;
_xLockDoor AT %Q* : BOOL := TRUE;
_xComStartup AT %I* : BOOL;
_xErrorAck AT %Q* : BOOL;
_tofErrorAck : TOF := (PT := T#500MS);
END_VAR
]]></Declaration>
<Implementation>
<ST><![CDATA[_xRun := NOT _xComStartup;
_rtrigDoorUnlock(CLK := _xRequestOpenDoor AND xRobotStopped);
IF _rtrigDoorUnlock.Q THEN
xStopRobot := (NOT xStopRobot);
_xLockDoor := (NOT _xLockDoor);
END_IF
// Reset safety group errors
_tofErrorAck(IN:= xConfirmAlarms, PT:= T#500MS, Q=> _xErrorAck, ET=> );]]></ST>
</Implementation>
</POU>
</TcPlcObject>