Matthias Heisig
483fa83149
Switch voltage low and high sequence in modbus error and warning register for consistency
2025-04-15 13:21:56 +02:00
Matthias Heisig
390b831286
Hardware reset button now triggers an alarm acknowledge signal
2025-04-14 19:46:02 +02:00
Matthias Heisig
f79cf27c0c
Finished first implementation of modbus error registers
2025-04-14 19:38:17 +02:00
Matthias Heisig
4a00a4c414
Added Modbus registers
2025-04-08 07:24:55 +02:00
Matthias Heisig
2221f6bab3
Minor bugfixes and future addons
2025-04-06 10:21:01 +02:00
Matthias Heisig
84e0e174a1
Fixed missing multistring handling in some modes
2025-02-14 16:14:07 +01:00
Matthias Heisig
4f0905d64a
Fixed some bugs in cycling mode
2025-02-14 15:42:27 +01:00
Matthias Heisig
2ded890dd4
Added multi string handling and balancing
2025-02-13 21:26:50 +01:00
Matthias Heisig
f9df0a5180
Added precharging to SafetyCheck
2025-02-10 08:44:52 +01:00
Matthias Heisig
0345f57a3f
Some refactoring
2025-01-17 08:08:37 +01:00
Matthias Heisig
39a02352f6
Iso and leackage error messages added
2024-09-10 16:54:17 +02:00
Matthias Heisig
d9f39953a0
Added shutdown when inverter error
2024-09-06 18:47:03 +02:00
Matthias Heisig
3d041c50c4
- Added new module status
...
- Added error messages for EtherCAT connection lost
2024-09-05 18:32:49 +02:00
Matthias Heisig
5e94ba4868
Merge branch 'feature/ManualModeSwitch' into develop
...
# Conflicts:
# PLC/PLC.tmc
# PLC/POUs/FB_String.TcPOU
# PLC/POUs/MAIN.TcPOU
# Uniper.tsproj
2024-08-30 14:32:11 +02:00
Matthias Heisig
08d2ffd136
Added string startup timeout
2024-08-30 13:12:42 +02:00
Matthias Heisig
112f7cb7d9
Added automatic manual mode change for all components if manual mode is selected, Added moving average filter to analog data
2024-08-26 22:19:29 +02:00
Matthias Heisig
58e511438e
Umstellung auf TwinCAT 4026
2024-07-29 07:33:50 +02:00
Matthias Heisig
0d9a4d9c72
WIP: Aktueller stand für fehlersuche Sensorrauschen
2024-05-22 17:43:26 +02:00
Matthias Heisig
cf0d144987
Reordered Modbus registers for Energielenker
2024-05-07 18:02:07 +02:00
Matthias Heisig
5c42d4db0a
Added ac phase currents to inverter data and copy it to modbus interface
2024-05-07 17:34:01 +02:00
Matthias Heisig
0ffff9be2a
EMS communication and Voltage optimizations
...
- Added data for EMS communication
- Added highest segment voltage for charging check
- Added lowest segment voltage for discharging check
2024-05-07 17:10:29 +02:00
Matthias Heisig
327f324be8
Implemented fixes and improvements during comissioning
...
- New Balancing mode
- HMI Interface for Inverterdata implemented
- Adjusted GVL_CONFIG values
- Read inverter data even when inverter is off
- Added OPC UA settings to inverter data hmi interface
- Added multisettings to safety project for strings
2024-05-06 11:05:33 +02:00
Matthias Heisig
b95033a155
First string implemented
2024-04-18 08:32:21 +02:00
Matthias Heisig
9ce3522a70
WIP: Inbetriebnahme vorladen
2024-04-11 19:06:45 +02:00
Matthias Heisig
ef26159a4f
Added safety program pre comissioning and started implementing different modes
2024-03-20 18:08:57 +01:00
Matthias Heisig
57987cb19f
Fixed Modbus register access
2024-01-17 11:26:11 +01:00
Matthias Heisig
4586e72a0e
Added inverter implementation
2024-01-05 16:27:39 +01:00
Matthias Heisig
bd0bbd9c8b
Added Simulation plc and removed unnecessary files from repository
2024-01-04 18:39:55 +01:00
Matthias Heisig
faa33db290
Projektdateien hinzufügen.
2024-01-04 15:15:26 +01:00