changed modbus communication
...
moved from all requests at the same time to one request after each other through state machine
2025-09-05 16:20:36 +02:00
Markus.Neukirch
f0e6143997
IBN changes
...
added sync units for cabinet temperature, changes in modbus interface to EMS (1.0.4 and 1.0.5), added error counter to modbus communication, lot of changes to kaco (faults, consecutive errors, bms error messages), isolation error ledge, allowed startbalancing when on shutdown, tower light integration
2025-09-05 14:24:37 +02:00
Matthias Heisig
9c6e28b83d
Added Kaco inverter implementation
...
- Added Kaco inverter implementation
- Small refactoring
- Added release inverter power signal for simultaneous start of the
inverters
2025-08-11 23:26:40 +09:00
Matthias Heisig
58f3c751d3
Some fixes before the FAT
...
- Refactored inverter Heartbeat check
- Added SafetyComError on EtherCAT checking
- Adjusted lower pressure value for safety plc from 200 mBar to 300mBar
2025-06-06 19:09:12 +02:00
Matthias Heisig
2f9f4df261
changes during start of safety check
...
- Refactoring of string fb
- Added pump safety interlocks for pressure segment inlet too low and too high
2025-06-02 19:51:57 +02:00
Matthias Heisig
1677d34d9c
Added Kaco inverter for sensor ripple testing
...
- Iso error in string will now only be active if the dc circuit breaker is not closed
- Added some delay between closing dc circuit breaker and enabling inverter so that the dc bus voltage can stabilize itself
2025-05-08 10:07:16 +02:00
Matthias Heisig
0db1fa523a
Sunspec heartbeat timer incrementation slowed down
2025-04-28 17:14:43 +02:00
Matthias Heisig
7b810b19d2
Implemented a better balancing algorith for string balancing
...
* Added error logging to inverter fb
* Changed HMI actual power feedback from dc to ac power
* Small config adjustments
2025-04-16 12:35:06 +02:00
Matthias Heisig
bbf60864db
Added inverter active signal to avoid triggering the isolation monitoring
2025-04-15 13:22:55 +02:00
Matthias Heisig
f79cf27c0c
Finished first implementation of modbus error registers
2025-04-14 19:38:17 +02:00
Matthias Heisig
2221f6bab3
Minor bugfixes and future addons
2025-04-06 10:21:01 +02:00
Matthias Heisig
2ded890dd4
Added multi string handling and balancing
2025-02-13 21:26:50 +01:00
Matthias Heisig
0345f57a3f
Some refactoring
2025-01-17 08:08:37 +01:00
Matthias Heisig
3d041c50c4
- Added new module status
...
- Added error messages for EtherCAT connection lost
2024-09-05 18:32:49 +02:00
Matthias Heisig
0d9a4d9c72
WIP: Aktueller stand für fehlersuche Sensorrauschen
2024-05-22 17:43:26 +02:00
Matthias Heisig
5c42d4db0a
Added ac phase currents to inverter data and copy it to modbus interface
2024-05-07 17:34:01 +02:00
Matthias Heisig
0ffff9be2a
EMS communication and Voltage optimizations
...
- Added data for EMS communication
- Added highest segment voltage for charging check
- Added lowest segment voltage for discharging check
2024-05-07 17:10:29 +02:00
Matthias Heisig
327f324be8
Implemented fixes and improvements during comissioning
...
- New Balancing mode
- HMI Interface for Inverterdata implemented
- Adjusted GVL_CONFIG values
- Read inverter data even when inverter is off
- Added OPC UA settings to inverter data hmi interface
- Added multisettings to safety project for strings
2024-05-06 11:05:33 +02:00
Matthias Heisig
b95033a155
First string implemented
2024-04-18 08:32:21 +02:00
Matthias Heisig
ef26159a4f
Added safety program pre comissioning and started implementing different modes
2024-03-20 18:08:57 +01:00
Matthias Heisig
57987cb19f
Fixed Modbus register access
2024-01-17 11:26:11 +01:00
Matthias Heisig
4586e72a0e
Added inverter implementation
2024-01-05 16:27:39 +01:00
Matthias Heisig
faa33db290
Projektdateien hinzufügen.
2024-01-04 15:15:26 +01:00